ovantelogo towersunset cablerail steelpole construction pipeline

 

ASTM D4541-02 Adhesion Pull-Off Test - TEC Services, Atlanta, GA

Steel coupons coated with Storm Greeter were subjected to adhesion pull-off tests alongside steel coupons coated with Chemthane 2260, supplied by Sabre Tubular Structures.

Storm Greeter averaged 270 psi bond strength (Profile: Galvanized finish, supplied by Valmont)

Chemthane averaged 395 psi bond strength (Plate coated and supplied by Sabre Tubular Structures)

____________________ ____________________

ASTM D6677-07 X-Cut Pull-Off Test - TEC Services, Atlanta, GA

In this test, an X cut is made in the coating. Tape is placed over the intersection of the cut and quickly removed with extreme force.

Storm Greeter scored perfect 10s!

What does it take to score a 10?

ASTM Standard - Coating is extremely difficult to remove; fragments no larger than approximately 0.8 by 0.8 mm (1/32 by 1/32 in) removed with great difficulty.

For information, please email us at: customerservice@ovantellc.com .................................... All products & processes discussed on this site are patent pending.
_____________________________________________________________________________________________________________________________